本文已被:浏览 1617次 下载 2212次
Received:April 03, 2014 Revised:May 12, 2014
Received:April 03, 2014 Revised:May 12, 2014
中文摘要: 针对显微图像测量系统的特点, 提出了一种结合标准显微标尺的标定方法. 该方法首先获取已知尺寸的显微标尺图像, 接着通过预处理及边缘检测分离出图像中的标尺刻度线, 然后基于Hough识别出长刻度线, 并计算刻度线对应的像素距离, 从而计算出标定系数. 标定过程中采用了现有的显微刻度尺, 使用方便. 实验结果表明, 该方法标定精度较高.
Abstract:A camera calibration method for micro-image measuring system is presented. Firstly the micro image of known size microscopic scale is obtained. Followed by pre-processing and edge detection, ruler lines can be cut out from the image. Then based on Hough lines, the longer ruler lines can be identified. So the calibration factor can be calculated by the physical distance and the corresponding pixel distance of the lines. The calibration objects are existing microscopic scales, so this method is easily applied. The experimental results show that calibration precision is high.
文章编号: 中图分类号: 文献标志码:
基金项目:浙江省自然科学基金(LY13F020029);宁波市重点科技计划项目(2013C11032)
引用文本:
高飞,袁晓阳,严建军,陈德顺,肖刚.基于Hough变换的显微图像测量系统标定算法.计算机系统应用,2014,23(12):160-164
GAO Fei,YUAN Xiao-Yang,YAN Jian-Jun,CHEN De-Shun,XIAO Gang.Camera Calibration Method for Micro-Image Measuring System Based on Hough Transform.COMPUTER SYSTEMS APPLICATIONS,2014,23(12):160-164
高飞,袁晓阳,严建军,陈德顺,肖刚.基于Hough变换的显微图像测量系统标定算法.计算机系统应用,2014,23(12):160-164
GAO Fei,YUAN Xiao-Yang,YAN Jian-Jun,CHEN De-Shun,XIAO Gang.Camera Calibration Method for Micro-Image Measuring System Based on Hough Transform.COMPUTER SYSTEMS APPLICATIONS,2014,23(12):160-164