中文摘要: 传统的电极导联心脏监护仪都是有线的,接触皮肤的,高功耗的。立足于非接触性,轻便性,低功耗,给出了基于MSP430-RF 无线套装的心跳监控系统的软硬件设计方法,该系统能够实时测量到人体的脉搏波形,并计算出每分钟心跳次数。系统已可实际运行,具有实时性强、低功耗、图形化界面友好的优点。
Abstract:The traditional electrode-lead heart monitoring systems are wired, and contact with skin, high power consumption. This paper form the non-contact, light, low-power, to conduct a suit based on MSP430-RF wireless heart monitoring system development. This paper designs the hardware functional circuit, and completes the PC preparation process. The system can measure the pulse waveform to the body in real-time, and calculate the number of heartbeats per minute, with a graphical interface displayed. The system has been achieved and can be run.